A. Hertzman, Photoelectric Plethysmography of the Fingers and Toes in Man, Experimental Biology and Medicine, vol.37, issue.3, pp.529-3400379727, 1937.
DOI : 10.3181/00379727-37-9630

W. Verkruysse, L. Svaasand, and J. Nelson, Remote plethysmographic imaging using ambient light, Optics Express, vol.16, issue.26, pp.21434-21479, 2008.
DOI : 10.1364/OE.16.021434.m003

URL : http://europepmc.org/articles/pmc2717852?pdf=render

L. Aarts, J. V. Cleary, J. Lieber, C. Nelson, J. et al., Non-contact heart rate monitoring utilizing camera photoplethysmography in the neonatal intensive care unit ??? A pilot study, Early Human Development, vol.89, issue.12, pp.943-951, 2013.
DOI : 10.1016/j.earlhumdev.2013.09.016

G. De-haan and J. V. , Robust Pulse Rate From Chrominance-Based rPPG, IEEE Transactions on Biomedical Engineering, vol.60, issue.10, pp.2878-86, 2013.
DOI : 10.1109/TBME.2013.2266196

D. Mcduff, S. Gontarek, and R. Picard, Improvements in Remote Cardiopulmonary Measurement Using a Five Band Digital Camera, IEEE Transactions on Biomedical Engineering, vol.61, issue.10, pp.2593-601, 2014.
DOI : 10.1109/TBME.2014.2323695

M. Poh, D. Mcduff, and R. Picard, Non-contact, automated cardiac pulse measurements using video imaging and blind source separation, Optics Express, vol.18, issue.10, pp.10762-74, 2010.
DOI : 10.1364/OE.18.010762.m003

M. Poh, D. Mcduff, and R. Picard, Advancements in Noncontact, Multiparameter Physiological Measurements Using a Webcam, IEEE Transactions on Biomedical Engineering, vol.58, issue.1, pp.7-11, 2011.
DOI : 10.1109/TBME.2010.2086456

URL : http://affect.media.mit.edu/pdfs/11.Poh-etal-TBME.pdf

A. Hyvärinen and E. Oja, Independent component analysis: algorithms and applications, Neural Networks, vol.13, issue.4-5, pp.4-5411, 2000.
DOI : 10.1016/S0893-6080(00)00026-5

W. Lu and J. Rajapakse, Constrained independent component analysis Advances in neural information processing systems 13, pp.570-76, 2000.

P. Comon, Independent component analysis, a new concept? Signal Process, pp.287-3140165, 1994.
DOI : 10.1016/0165-1684(94)90029-9

D. Djuwari, K. Kumar, D. Palaniswami, and M. , Limitations of ICA for Artefact Removal, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference, pp.4685-4693, 2005.
DOI : 10.1109/IEMBS.2005.1615516

URL : http://researchbank.rmit.edu.au/eserv/rmit:1577/n2006005092.pdf

. Macwan, Remote photoplethysmography with constrained ICA using periodicity and chrominance constraints, BioMedical Engineering OnLine, vol.49, issue.2, p.22, 2018.
DOI : 10.1117/12.463573

URL : https://hal.archives-ouvertes.fr/hal-01806700

B. Holton, K. Mannapperuma, P. Lesniewski, and J. Thomas, Signal recovery in imaging photoplethysmography, Physiological Measurement, vol.34, issue.11, pp.1499-5110967, 1088.
DOI : 10.1088/0967-3334/34/11/1499

W. Wang, S. Stuijk, D. Haan, and G. , Exploiting Spatial Redundancy of Image Sensor for Motion Robust rPPG, IEEE Transactions on Biomedical Engineering, vol.62, issue.2, pp.415-440, 2015.
DOI : 10.1109/TBME.2014.2356291

URL : https://pure.tue.nl/ws/files/4010457/675672868790305.pdf

G. De-haan and A. Van-leest, Improved motion robustness of remote-PPG by using the blood volume pulse signature, Physiological Measurement, vol.35, issue.9, pp.1913-1939, 2014.
DOI : 10.1088/0967-3334/35/9/1913

W. Wang, D. Brinker, A. Stuijk, S. , D. Haan et al., Algorithmic Principles of Remote PPG, IEEE Transactions on Biomedical Engineering, vol.64, issue.7, p.99, 2016.
DOI : 10.1109/TBME.2016.2609282

URL : https://pure.tue.nl/ws/files/31563684/TBME_00467_2016_R1_preprint.pdf

L. Feng, L. Po, X. Xu, Y. Li, C. Cheung et al., Dynamic ROI based on K-means for remote photoplethysmography, 2015 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP), pp.1310-1324, 2015.
DOI : 10.1109/ICASSP.2015.7178182

S. Bobbia, Y. Benezeth, and J. Dubois, Remote photoplethysmography based on implicit living skin tissue segmentation, 2016 23rd International Conference on Pattern Recognition (ICPR), 2016.
DOI : 10.1109/ICPR.2016.7899660

URL : https://hal.archives-ouvertes.fr/hal-01356059

D. Brennan, Linear Diversity Combining Techniques, Proceedings of the IRE, vol.47, issue.6, pp.1075-102, 1959.
DOI : 10.1109/JRPROC.1959.287136

M. Kumar, A. Veeraraghavan, and A. Sabharwal, DistancePPG: Robust non-contact vital signs monitoring using a camera, Biomedical Optics Express, vol.6, issue.5, p.1565, 2015.
DOI : 10.1364/BOE.6.001565

URL : http://europepmc.org/articles/pmc4467696?pdf=render

X. Li, J. Chen, G. Zhao, and M. Pietikäinen, Remote Heart Rate Measurement from Face Videos under Realistic Situations, 2014 IEEE Conference on Computer Vision and Pattern Recognition
DOI : 10.1109/CVPR.2014.543

M. Butler, J. Crowe, B. Hayes-gill, and P. Rodmell, Motion limitations of non-contact photoplethysmography due to the optical and topological properties of skin, Physiological Measurement, vol.37, issue.5, pp.27-370967, 2016.
DOI : 10.1088/0967-3334/37/5/N27

G. Edwards, C. Taylor, and T. Cootes, Interpreting face images using active appearance models, Proceedings Third IEEE International Conference on Automatic Face and Gesture Recognition, pp.300-305, 1998.
DOI : 10.1109/AFGR.1998.670965

URL : http://www.isbe.man.ac.uk/~bim/Papers/fg98.ps.gz

H. Tasli, A. Gudi, D. Uyl, and M. , Remote PPG based vital sign measurement using adaptive facial regions, 2014 IEEE International Conference on Image Processing (ICIP)
DOI : 10.1109/ICIP.2014.7025282

Y. Sun and N. Thakor, Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging, IEEE Transactions on Biomedical Engineering, vol.63, issue.3, pp.463-77, 2016.
DOI : 10.1109/TBME.2015.2476337

URL : http://europepmc.org/articles/pmc4822420?pdf=render

D. Mcduff, J. Estepp, A. Piasecki, and E. Blackford, A survey of remote optical photoplethysmographic imaging methods, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), pp.6398-404, 2015.
DOI : 10.1109/EMBC.2015.7319857

L. Tarassenko, M. Villarroel, A. Guazzi, J. J. Clifton, D. Pugh et al., Non-contact video-based vital sign monitoring using ambient light and auto-regressive models, Physiological Measurement, vol.35, issue.5, pp.807-310967, 2014.
DOI : 10.1088/0967-3334/35/5/807

URL : http://iopscience.iop.org/article/10.1088/0967-3334/35/5/807/pdf

G. Tsouri, S. Kyal, S. Dianat, and L. Mestha, Constrained independent component analysis approach to nonobtrusive pulse rate measurements, Journal of Biomedical Optics, vol.17, issue.7, p.770111, 2012.
DOI : 10.1109/TNN.2004.836795

URL : https://www.spiedigitallibrary.org/journals/Journal-of-Biomedical-Optics/volume-17/issue-7/077011/Constrained-independent-component-analysis-approach-to-nonobtrusive-pulse-rate-measurements/10.1117/1.JBO.17.7.077011.pdf

A. Hyvarinen, Fast and robust fixed-point algorithms for independent component analysis, IEEE Transactions on Neural Networks, vol.10, issue.3, pp.626-660, 1999.
DOI : 10.1109/72.761722

URL : http://www.cs.helsinki.fi/u/ahyvarin/papers/TNN99_reprint.pdf

D. Bertsekas, Constrained optimization and Lagrange multiplier methods, 1985.

R. Byrd, J. Gilbert, and J. Nocedal, A trust region method based on interior point techniques for nonlinear programming, Mathematical Programming, vol.89, issue.1, pp.149-85, 2000.
DOI : 10.1007/PL00011391

URL : https://hal.archives-ouvertes.fr/inria-00073794

C. Conaire, O. Connor, N. Smeaton, and A. , Detector adaptation by maximising agreement between independent data sources. CVPR, 2007.
DOI : 10.1109/cvpr.2007.383448

URL : http://doras.dcu.ie/437/1/ieee_otcbvs_2007.pdf

M. Tarvainen, P. Karjalainen, and P. , An advanced detrending method with application to HRV analysis, IEEE Transactions on Biomedical Engineering, vol.49, issue.2, pp.172-177, 2002.
DOI : 10.1109/10.979357

M. Lewandowska, J. Ruminski, T. Kocejko, and J. Nowak, Measuring pulse rate with a webcam; a non-contact method for evaluating cardiac activity federated conference on computer science and information systems (FedCSIS), pp.2011-405, 2011.

M. Hülsbusch, Ein bildgestütztes, funktionelles Verfahren zur optoelektronischen Erfassung der Hautperfusion, Anesth Analg, vol.145, 2008.